Description: | The wind speed and direction values for 2m, 10m and 20m dropped to zero at 14:20 GMT. The
cause was a power failure due to failed power line. Power spikes caused the wind sensors
to revert to default settings for communications and measurements. The following is a
list of dates that the various sensors came back online:
2m wind problem ending on 01/28/2010 @ 2330GMT
20m wind problem ending on 02/04/2010 @ 2230GMT
10m wind problem ending on 02/05/2010 @ 2100GMT
40m winds were already failing and documented in DQPR 2262 and PIF P091030.1.
The MET system was also affected and documented in DQPR 2337. |