DQRID : D100510.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
03/19/2010193005/05/20101745Incorrect
more
Subject:
SGP/EBBR/E15 - Sensible and Latent Heat Fluxes Low
(Net Radiation too low)
DataStreams:sgp5ebbrE15.b1, sgp30ebbrE15.b1, sgp15ebbrE15.b1
Description:
Sensible and Latent Heat Fluxes were measured as being low because of damage to the net 
radiometer.

The Sensible and Latent Heat fluxes can be approximated by taking the ratio of the daytime 
SIRS net radiation to EBBR net radiation, and then multiplying the Sensible and Latent 
Heat Fluxes by that ratio.
Suggestions: 
Measurements:sgp5ebbrE15.b1:
  • net_radiation
more
sgp15ebbrE15.b1:
  • net_radiation_mv
more
sgp30ebbrE15.b1:
  • net_radiation
  • latent_heat_flux
  • sensible_heat_flux
more

Close this window