DQRID : D121018.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/27/2011200001/16/20131752Suspect
more
Subject:
NSA/WSACR/C1 - Mean Doppler Velocity sign reversed
DataStreams:nsawsacrhsrhiC1.a1, nsawsacrppiC1.a1, nsawsacrcwrhiC1.a1, nsawsacrawrhiC1.a1,
nsawsacrblrhiC1.a1, nsawsacrvptC1.a1, nsawsacrspeccmaskxpolC1.a0, nsawsacrspeccmaskcopolC1.a0,
nsawsacrrhiC1.a1
Description:
The signs of the mean_doppler_velocity field values are incorrect.  The ARM convention for 
this field is that positive velocities indicate motion away from the radar.  However, 
the velocity data in these files have their signs reversed, so that motion TOWARD the radar 
has a positive sign.
Suggestions: 
Multipy the mean_doppler_velocity values by -1 prior to using the data.  This will 

result in motion away from the radar having a positive sign.
Measurements:nsawsacrcwrhiC1.a1:
  • mean_doppler_velocity
more
nsawsacrrhiC1.a1:
  • mean_doppler_velocity
more
nsawsacrawrhiC1.a1:
  • mean_doppler_velocity
more
nsawsacrhsrhiC1.a1:
  • mean_doppler_velocity
more
nsawsacrppiC1.a1:
  • mean_doppler_velocity
more
nsawsacrspeccmaskcopolC1.a0:
  • mean_doppler_velocity
more
nsawsacrspeccmaskxpolC1.a0:
  • mean_doppler_velocity
more
nsawsacrvptC1.a1:
  • mean_doppler_velocity
more
nsawsacrblrhiC1.a1:
  • mean_doppler_velocity
more