DQRID : D150327.7
Start DateStart TimeEnd DateEnd Time Data Quality Metric
03/01/2015191603/08/20150043Incorrect
more
Subject:
OLI/GNDRAD/M1 - Environmental
DataStreams:oligndrad60sM1.b1, oligndrad20sM1.a0
Description:
AC power out during affected time range affecting ventilator fans and heaters for 
up_short_hemisp, and up_long_hemisp radiometers.
Suggestions: 
Do not use data
Measurements:oligndrad20sM1.a0:
  • inst_up_long_hemisp_dome_resist
  • inst_up_long_hemisp_tp
  • inst_up_long_hemisp_case_resist
  • inst_up_short_hemisp
more
oligndrad60sM1.b1:
  • up_short_hemisp_min
  • inst_up_long_hemisp_dome_temp
  • up_long_hemisp_std
  • up_long_hemisp_max
  • inst_up_long_hemisp_case_temp
  • inst_up_long_hemisp_tp
  • up_short_hemisp_std
  • up_short_hemisp_max
  • up_long_hemisp
  • up_short_hemisp
  • up_long_hemisp_min
more