SGP/SEBS/E31 - Reprocessed and Corrected:Net Radiation Measurements Incorrect
DataStreams:sgpsebsE31.b1
Description:
DATA REPROCESSED and CORRECTED: 

The net radiation measurements were incorrect because the data logger program used the 
wrong calibration coefficients.
The raw data were modified to recalculate the calibration coefficients and the SEBS data 
were reprocessed.

The data were archived in May 2016. Please retrieve the reprocessed data for use in your 
analysis.

ORIGINAL DQR CATEGORY: Red( Incorrect)

REPROCESSED and CORRECTED DATA ARCHIVED:2016-05-17

REPROCESS IDENTIFICATION NUMBER: RID 1389

---------------------------------------------------
--- ORIGINAL DQR DESCRIPTION ---
---------------------------------------------------


Net radiation measurements incorrect because the data logger program used the wrong 
calibration coefficients.