DQRID : D170403.6
Start DateStart TimeEnd DateEnd Time Data Quality Metric
11/15/2016000003/22/20171630Incorrect
more
Subject:
SGP/EBBR/E11 - Reprocess: Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp5ebbrE11.b1, sgp15ebbrE11.b1, sgp30ebbrE11.b1
Description:
A wiring mistake caused the top and bottom temperature measurements to be incorrect (top 
and bottom relative humidity probe temperatures used to determine vapor pressure were 
correct). Thus the sensible and latent heat fluxes were not correctly calculated.
Suggestions: 
Measurements:sgp15ebbrE11.b1:
  • temp_air_right
  • temp_air_left
more
sgp5ebbrE11.b1:
  • temp_air_bottom
  • temp_air_top
more
sgp30ebbrE11.b1:
  • sensible_heat_flux
  • temp_air_top
  • latent_heat_flux
  • temp_air_bottom
  • bowen_ratio
more

Close this window