DQRID : D170516.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
02/08/2017102602/08/20171438Incorrect
02/27/2017194402/28/20171408Incorrect
02/07/2017042102/07/20171522Incorrect
02/23/2017065402/23/20171546Incorrect
02/04/2017120602/06/20171552Incorrect
02/10/2017215402/13/20171556Incorrect
02/01/2017091702/01/20171445Incorrect
02/17/2017142602/17/20171644Incorrect
02/26/2017085802/27/20171538Incorrect
02/18/2017081402/22/20170416Incorrect
02/10/2017082202/10/20171436Incorrect
02/15/2017141402/15/20171758Incorrect
02/14/2017124502/14/20171421Incorrect
02/16/2017144902/17/20170046Incorrect
more
Subject:
SGP/PSAP/E13 - Invalid data from Transmission < 0.7
DataStreams:sgpaospsap3w1mE13.b1, sgpaospsap3wE13.b1, sgpaospsaprE13.a0, sgpaospsap3w1sE13.b1,
sgpaospsap3wE13.00, sgpaospsap3wE13.01, sgpaospsap3wE13.a1
Description:
Data with Transmission less than 0.7 is not valid.  No dilution at SGP so Operators 
couldn't always change filters regularly.
Suggestions: 
Do not use data
Measurements:sgpaospsap3w1sE13.b1:
  • Ba_B_Weiss
  • sample_flow_rate
  • Ba_B_raw
  • impactor_state
  • dilution_correction_factor
  • filter_unstable
  • spot_size_area
  • Ba_G_Weiss
  • sample_volume
  • Ba_R_raw
  • transmittance_blue
  • transmittance_green
  • transmittance_red
  • Ba_G_raw
  • Ba_R_Weiss
more
sgpaospsap3wE13.a1:
  • mass_flow
  • transmittance_R
  • Ba_B_PSAP3W
  • Ba_R_PSAP3W
  • dilution_flow_setpoint
  • dilution_flow_valve_position
  • transmittance_B
  • Ba_G_PSAP3W
  • transmittance_G
  • dilution_flow
more
sgpaospsap3wE13.00:
  • Raw data stream - documentation not supported
more
sgpaospsap3wE13.01:
  • dilution_flow_valve_position
  • transmittance_G
  • transmittance_B
  • Ba_B_PSAP3W
  • mass_flow
  • transmittance_R
  • Ba_R_PSAP3W
  • dilution_flow_setpoint
  • dilution_flow
  • Ba_G_PSAP3W
more
sgpaospsap3wE13.b1:
  • dilution_flow_setpoint
  • transmittance_green
  • transmittance_green_normalization_factor
  • absorbance_blue
  • seconds_after_transition
  • impactor_state
  • filter_unstable
  • absorbance_green
  • absorbance_red
  • tr_blue
  • dilution_correction_factor
  • dilution_flow_valve_position
  • transmittance_red_raw
  • transmittance_green_raw
  • transmittance_red_normalization_factor
  • tr_green
  • sample_flow_rate
  • transmittance_blue
  • dilution_flow
  • tr_red
  • transmittance_red
  • transmittance_blue_normalization_factor
  • transmittance_blue_raw
  • spot_size_area
more
sgpaospsap3w1mE13.b1:
  • Ba_G_Weiss
  • Ba_R_Weiss
  • impactor_state
  • Ba_G_raw
  • transmittance_red
  • sample_volume
  • sample_flow_rate
  • Ba_B_Weiss
  • transmittance_green
  • spot_size_area
  • transmittance_blue
  • Ba_R_raw
  • Ba_B_raw
more
sgpaospsaprE13.a0:
  • flags
  • mass_flow
  • red_overflow_count
  • dark_overflow_count
  • red_sample_count
  • red_reference_sum
  • red_signal_sum
  • dark_sample_count
  • dark_reference_sum
  • blue_sample_count
  • blue_overflow_count
  • mass_flow_output
  • green_sample_count
  • green_signal_sum
  • dark_signal_sum
  • green_overflow_count
  • blue_signal_sum
  • blue_reference_sum
  • green_reference_sum
more

Close this window