DQRID : D170517.3
Start DateStart TimeEnd DateEnd Time Data Quality Metric
03/16/2017050003/16/20171543Incorrect
03/07/2017180903/08/20171410Incorrect
03/02/2017150203/02/20171916Incorrect
03/23/2017202103/24/20171437Incorrect
03/08/2017231903/09/20171509Incorrect
03/18/2017014803/20/20171416Incorrect
03/03/2017143303/03/20171608Incorrect
03/01/2017005203/01/20172357Incorrect
03/21/2017010303/21/20171325Incorrect
03/22/2017224903/23/20171410Incorrect
03/25/2017160803/27/20171431Incorrect
03/17/2017024103/17/20171506Incorrect
03/28/2017215103/29/20171420Incorrect
03/21/2017165703/22/20171411Incorrect
03/15/2017031203/15/20171901Incorrect
03/09/2017225703/10/20171510Incorrect
03/14/2017084103/14/20171348Incorrect
03/28/2017045103/28/20171409Incorrect
03/11/2017112603/13/20171625Incorrect
more
Subject:
SGP/PSAP/E13 - Transmission less than 0.7
DataStreams:sgpaospsap3w1mE13.b1, sgpaospsap3wE13.b1, sgpaospsaprE13.a0, sgpaospsap3w1sE13.b1,
sgpaospsap3wE13.00, sgpaospsap3wE13.01, sgpaospsap3wE13.a1
Description:
Periods where Transmission is less than 0.7 due to Operator unable to change the filter.
Suggestions: 
Do not use data
Measurements:sgpaospsap3w1sE13.b1:
  • Ba_B_Weiss
  • sample_flow_rate
  • Ba_B_raw
  • impactor_state
  • dilution_correction_factor
  • filter_unstable
  • spot_size_area
  • Ba_G_Weiss
  • sample_volume
  • Ba_R_raw
  • transmittance_blue
  • transmittance_green
  • transmittance_red
  • Ba_G_raw
  • Ba_R_Weiss
more
sgpaospsap3wE13.a1:
  • mass_flow
  • transmittance_R
  • Ba_B_PSAP3W
  • Ba_R_PSAP3W
  • dilution_flow_setpoint
  • dilution_flow_valve_position
  • transmittance_B
  • Ba_G_PSAP3W
  • transmittance_G
  • dilution_flow
more
sgpaospsap3wE13.00:
  • Raw data stream - documentation not supported
more
sgpaospsap3wE13.01:
  • dilution_flow_valve_position
  • transmittance_G
  • transmittance_B
  • Ba_B_PSAP3W
  • mass_flow
  • transmittance_R
  • Ba_R_PSAP3W
  • dilution_flow_setpoint
  • dilution_flow
  • Ba_G_PSAP3W
more
sgpaospsap3wE13.b1:
  • dilution_flow_setpoint
  • transmittance_green
  • transmittance_green_normalization_factor
  • absorbance_blue
  • seconds_after_transition
  • impactor_state
  • filter_unstable
  • absorbance_green
  • absorbance_red
  • tr_blue
  • dilution_correction_factor
  • dilution_flow_valve_position
  • transmittance_red_raw
  • transmittance_green_raw
  • transmittance_red_normalization_factor
  • tr_green
  • sample_flow_rate
  • transmittance_blue
  • dilution_flow
  • tr_red
  • transmittance_red
  • transmittance_blue_normalization_factor
  • transmittance_blue_raw
  • spot_size_area
more
sgpaospsap3w1mE13.b1:
  • Ba_G_Weiss
  • Ba_R_Weiss
  • impactor_state
  • Ba_G_raw
  • transmittance_red
  • sample_volume
  • sample_flow_rate
  • Ba_B_Weiss
  • transmittance_green
  • spot_size_area
  • transmittance_blue
  • Ba_R_raw
  • Ba_B_raw
more
sgpaospsaprE13.a0:
  • flags
  • mass_flow
  • red_overflow_count
  • dark_overflow_count
  • red_sample_count
  • red_reference_sum
  • red_signal_sum
  • dark_sample_count
  • dark_reference_sum
  • blue_sample_count
  • blue_overflow_count
  • mass_flow_output
  • green_sample_count
  • green_signal_sum
  • dark_signal_sum
  • green_overflow_count
  • blue_signal_sum
  • blue_reference_sum
  • green_reference_sum
more

Close this window