Description: | DQR No: Platform: SGPSONDEC1
Subject: Bad surface values in sounding 4/17/95 14:29
Date Submitted: 4/19/95
Submitted By: Barry Lesht _X_ Instrument Mentor
___ EST Member
___ Science Team Member
___ Other _____________________________
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.
Platform/Measurement: All
What level data: (raw,a0,a1,b1,c1 etc):
What location was the data collected at: SGP/CF
Period of time in question
Begin Date 4/17/95 Time 14:29 (GMT)
End Date 4/17/95 Time 15:51 (GMT)
Data should be labeled:
___ questionable ___ All data fields affected
_X_ incorrect _X_ Only some data fields affected
___ wrong calibration
___ others
Discussion of Problem:
The operator entered incorrect surface values for both RH and pressure.
Because of the way altitude is calculated, the incorrect pressure value
has the effect of making all subsequent altitude values incorrect. The
RH error only affects the first sample.
Other observations/measurements impacted by this problem:
Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)
Flag data.
Data Processing Notes Date |