Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/02/1997 | 2004 | 09/04/1997 | 2057 | Incorrect |
Subject: | SGP/TWR/C1 - 25m Low battery voltage affected data |
DataStreams: | sgp1twr25mC1.a0, sgp30twr25mC1.a1 |
Description: | Shortly after 2003 GMT on 2 September 1997 a GFCI circuit breaker tripped in the tower base AC box, resulting in a drop in CR21X voltage of 0.4 volts in seven minutes. This resulted in a steady drop in battery voltage for the next 30 hours, and incorrect, out of range, or missing values for temp, rh, and vap_pres. |
Suggestions: | |
Measurements: | sgp1twr25mC1.a0: more
sgp30twr25mC1.a1: more |