DQRID : D971111.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
07/14/1997090010/29/19972000Incorrect
more
Subject:
SGP/EBBR/E8 - Reprocess: SHF2 Incorrect
DataStreams:sgp30ebbrE8.b1, sgp15ebbrE8.b1
Description:
Soil heat flow probe #2 outputted incorrect, large positive values during the
period indicated.  Replacement of the probe on 29 October 1997 corrected the
problem.  The serial number of the probe replaced is 923025 and of the
replacement probe is 923110.

The data affected (and thus incorrect) includes:

15 minute: mv_hft2
30 minute: shf2, c_shf2, g2, ave_shf, e, h.

The latent and sensible heat fluxes can be recalculated by using only soil
heat flows 1, and 3 through 5 to calculate the average soil heat flow,

ave_shf = (g1 + g3 + g4 + g5)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(e + ave_shf + q)
Suggestions: 
Measurements:sgp15ebbrE8.b1:
  • soil_heat_flow_2_mv
more
sgp30ebbrE8.b1:
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • sensible_heat_flux
  • corr_soil_heat_flow_2
  • soil_heat_flow_2
  • surface_soil_heat_flux_avg
more

Close this window