Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/01/1998 | 0000 | 08/31/1998 | 2359 | Does not affect quality |
Subject: | Overview of Automated QA - August 1998 |
DataStreams: | sgp05okmX1.00, sgp15okmX1.00, sgp15okmX1.a1, sgp05okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the August 1998 Oklahoma Mesonet data. here are a few special events that were flagged by the automatic qa that you may want to be aware of. These include: * BRIS TS05 - (August 1 - August 31) The automatic QA created 15-20 suspect flags and a few warning flags each day for this site. We believe the sensor to be ok; however, the sod plot overlying the sensor was likely dead due to the drought this summer. The data should be used with caution. * The following list includes stations which experienced significant thunderstorm outflow. These events were usually isolated in nature, and therefore the data (typically TAIR) appeared to be spatially "off". We have investigated these events, and deem the data to be good. You can ignore the flags: OILT TAIR (August 2) TALI TAIR (August 3) ARDM and MTHE TAIR (August 7) BOWL TAIR (August 8) BREC TAIR and HOBA TA9M/TB05 (August 10) MTHE TAIR (August 12) PAWN TAIR (August 13) COPA TAIR (August 26) -Chris qamgr@redrock.ocs.ou.edu =========================================================================== == OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of August, 1998 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) =========================================================================== ===== Notes: The NINN site was moved approximately 7 feet from its original location on August 18 due to a water main break underneath the site. It really WAS that dry... The technicians checked a number of rain gauges during the month that were suspected of under-reporting. HOLL was high on the list, since the site had observed only .03 inches of rainfall over the past 90 days. The gauge checked out fine, and Bill Wyatt reported that "the general appearance of the area indicated that children as old as 4 or 5 may not have seen rain in their lifetime." We also had a handful of soil temperatures flagged as 'suspect' because they have been repeatedly failing the spatial test during the hot after- noons. The recent rainfall across the state will hopefully help us better evaluate which sensor are biased, and which sensors are simply reporting the conditions of the dry cracked ground. And now, on to the report... =========================================================================== ===== TAIR Current: None Added: None Resolved: #1974 SPEN Horse broke the instrument; repaired RELH Current: None Added: None Resolved: #1814 MARS Spider webs cleaned on probe cap #2005 GUTH Replaced sensor after failing mesocomp #2001 SPEN Faulty sensor replaced WDIR Current: None Added: None Resolved: #2019 NINN Tower moved; reset wind direction WSPD Current: None Added: None Resolved: #1913 SPEN Nose cone, nut, and prop replaced PRES Current: #2048 FTCB Sensor sticking and producing barometer errors #2049 SULP Sensor reporting continuous spikes and dips #2016 KENT Sensor sticking and reporting barometer errors since installation Added: None Resolved: #2017 APAC Barometer brough to lab for test SRAD Current: #1839 HOOK Reporting -1 for extended periods at night Added: None Resolved: #1987 OKMU Sensor checked out OK; bird probably responsible for suspicious afternoon readings RAIN Current: #2030 WOOD Sensor reporint 0.00" during numerous rain events Added: None Resolved: #1986 HOLL Field drip test showed gauge to be fine #1972 CHEY Field drip test showed gauge to be fine #1973 BUTL Field drip test showed gauge to be fine #1984 MIAM Gauge cleaned and no problems found TA9M Current: #1989 HUGO Monthly QA suggests 2 C cool bias Added: None Resolved: None WS2M Current: None Added: None Resolved: #1952 CLAY New CR10T corrected continuous 0.0 WS2M reports TS10 Current: #2021 SEIL Sensor reporting erroneous dips Added: None Resolved: None TB10 Current: #1779 WILB Monthly QA suggests 4 C cool bias #2003 WOOD Sensor reporting 8 C cooler than neighbors #2020 SEIL Sensor reporting erroneous dips #2052 BYAR Sensor reporting long-duration offsets of 5-10 C and numerous spikes Added: None Resolved: #1970 NINN Water main burst required sensor to be moved TS05 Current: #1847 SHAW Data suggests 3-6 C cool bias Added: None Resolved: None TB05 Current: #1808 WOOD Monthly QA suggests possible 4 C warm bias #1878 PAUL Sensor reporting values below 0 C #1899 IDAB Sensor reporting over 50 C #1988 EUFA Sensor reporting cooler than TB10 at all times of day #2015 ELRE Sensor reporting 8 C warmer than neighbors #2036 BOIS Sensor has diurnal swing from 11 C - 56 C Added: None Resolved: #1971 NINN Water main burst required sensor to be moved TS30 Current: #1956 SHAW Data suggests TS05 and TS30 wires are crossed Added: None Resolved: None --------------------------------------------------------------------------- ---- ARS QA REPORT --------------------------------------------------------------------------- ---- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: #2031 A166 Failed mesocomp and replaced SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #2032 A132 Spider webs removed from gauge TS05 Current: #1924 A157 Awaiting new sensor after site move Added: None Resolved: None TS10 Current: #1927 A157 Awaiting new sensor after site move Added: None Resolved: #2000 A161 Sensor found to be 20 C too high; replaced TS15 Current: #1926 A157 Awaiting new sensor after site move #2029 A146 Sensor reporting below -100 C Added: None Resolved: #1985 A154 Sensor found to be 9.5 C too warm; replaced TS30 Current: #1925 A157 Awaiting new sensor after site move Added: None Resolved: #2002 A167 Gopher-damaged sensor replaced =========================================================================== === LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== === Chris Fiebrich September 17, 1998 |
Suggestions: | Users of these data should obtain the detailed quality assurance information from ARM |
Measurements: | sgp05okmX1.a1: more
sgp05okmX1.00: more sgp15okmX1.a1: more sgp15okmX1.00: more |