DQRID : D990129.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
11/24/1998131511/24/19981530Incorrect
more
Subject:
SGP/EBBR/E12 - All Temperature Measurements Incorrect
DataStreams:sgp5ebbrE12.b1, sgp30ebbrE12.b1, sgp15ebbrE12.b1
Description:
Failure of the multiplexer connection for the reference temperature 
thermocouple in the control box or a problem with the Campbell CR10
bridge circuitry caused all air and soil temperature measurements
to be incorrect. Therefore, the computed 30 minute bowen, e, and h were 
also incorrect.
Suggestions: 
Measurements:sgp15ebbrE12.b1:
  • soil_temp_4_rr
  • temp_trh_right_rr
  • temp_trh_left_rr
  • soil_temp_2_rr
  • temp_reference_rr
  • temp_air_left
  • soil_temp_3_rr
  • soil_temp_5_rr
  • soil_temp_1_rr
  • temp_air_right
more
sgp5ebbrE12.b1:
  • temp_trh_top
  • temp_air_top
  • temp_air_bottom
  • temp_reference
  • temp_trh_bottom
more
sgp30ebbrE12.b1:
  • soil_temp_3
  • soil_temp_2
  • soil_temp_5
  • soil_temp_4
  • temp_air_bottom
  • soil_temp_1
  • bowen_ratio
  • temp_reference
  • sensible_heat_flux
  • latent_heat_flux
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
more