DQRID : D000225.2
Start DateStart TimeEnd DateEnd Time
07/27/1999153007/27/19991530
more
Subject:
SGP/EBBR- EBBR E15 Air Temperatures Incorrect
DataStreams:sgp5ebbrE15.b1, sgp30ebbrE15.b1, sgp15ebbrE15.b1
Description:
When the reference temperature sensor was being replaced, the left and
right thermocouple air temperatures and humidity probe temperatures 
were incorrect.

Affected data values were:

5 Minute:  tref, tair_top, tair_bot, thum_top, thum_bot, vp_top, vp_bot
15 minute: rr_tref, rr_thum_l, rr_thum_r, tair_r, tair_l
30 minute: tref, tair_top, tair_bot, thum_top, thum_bot, vp_top, vp_bot,
           bowen, e, h
Suggestions: 
Measurements:sgp5ebbrE15.b1:
  • Top T/RH sensor temperature(temp_trh_top)
  • Top air temperature(temp_air_top)
  • Bottom vapor pressure(vapor_pressure_bottom)
  • Reference temperature in enclosure(temp_reference)
  • Bottom air temperature(temp_air_bottom)
  • Top vapor pressure(vapor_pressure_top)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
more
sgp15ebbrE15.b1:
  • Left air temperature(temp_air_left)
  • Reference temperature in enclosure (resistance ratio)(temp_reference_rr)
  • Right T/RH sensor temperature (resistance ratio)(temp_trh_right_rr)
  • Right air temperature(temp_air_right)
  • Left T/RH sensor temperature (resistance ratio)(temp_trh_left_rr)
more
sgp30ebbrE15.b1:
  • Bottom air temperature(temp_air_bottom)
  • Bottom vapor pressure(vapor_pressure_bottom)
  • Top vapor pressure(vapor_pressure_top)
  • Surface latent heat flux(latent_heat_flux)
  • Reference temperature in enclosure(temp_reference)
  • Surface sensible heat flux(sensible_heat_flux)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
  • Top air temperature(temp_air_top)
  • Top T/RH sensor temperature(temp_trh_top)
  • Bowen ratio(bowen_ratio)
more

Close this window