Subject:
SGP/OKM Overview of Automated QA - June 2000
DataStreams:sgp05okmX1.b1, sgp15okmX1.b1, sgp15okmX1.a1, sgp05okmX1.a1
Description:
Below is an overview from Chris Fiebrich, the Mesonet QA manager
of the automated quality assurance results for the June 2000
Oklahoma Mesonet data.

===============================================================
Notes:
The Mesonet Technicians completed Spring Pass 2000 on June 30.
The point comparisons they performed on the TAIR, RELH, PRES,
SRAD, and RAIN parameters were very useful for QA of Mesonet
data.  A number of sensors reporting slightly outside of the
Mesonet's acceptable error ranges were identified.

Many site photos were taken during Spring Pass 2000 to document
vegetation cover around the bare and sod soil temperature plots,
the soil heat flux sensors, and the soil moisture plots at each
station.  Look for those pictures along with the site visitation
forms indicating the technician's notes to be available on the 
web next month.

One more note... The monthly analysis for June identified the
very heavy rains that fell over east Oklahoma during mid to late
June.  Westville took top honors with a June total of 
17.04 inches!
================================================================

TAIR    Current:        None
        Added:          None
        Resolved:       #5011 SLAP Replaced malfunctioning sensor        

RELH    Current:        #5014 ALV2 RELH to 108%
                        #5074 WIST RELH to 112%
                        #5082 ADAX Sensor found to be 6% high during
                              Spring Pass 2000 comparison
                        #5083 BBOW Sensor found to be 20% high during
                              Spring Pass 2000 comparison
                        #5084 WAUR Sensor found to be 7% high during
                              Spring Pass 2000 comparison
                        #5102 KENT Sensor stuck at 0% for extended
                              period
        Added:          None
        Resolved:       #4948 MAYR Replaced bad sensor            
                        #5006 CAMA Replaced bad sensor
                        #5010 SLAP Replaced bad sensor
                        #5013 ARDM Replaced sensor that failed mesocomp
                        #5077 WEST Replaced sensor stuck at 0%
                        #5087 CENT Replaced sensor found to have
                              5.3% high bias during spring pass 2000
                        #5094 MARE Replaced sensor found to have
                              5.9% high bias during spring pass 2000
                        #5110 BUFF Replaced sensor found to have
                              6.0% high bias during spring pass 2000
                     
 
WDIR    Current:        None 
        Added:          None
        Resolved:       None 

WSPD    Current:        #4976 BYAR Sensor sporadically 4-5
                              m/s slower than speed at 9 m
        Added:          None
        Resolved:       #5093 MARE Replaced sensor with noisy bearings
                        #5120 CLAR Replaced sensor with noisy bearings

PRES    Current:        #5086 RETR Sensor found to be .72 mb high
                              during Spring Pass 2000 comparison
        Added:          None
        Resolved:       #4980 RETR Found tube clogged with bug
                        #5046 WIST Replaced bad barometer 

SRAD    Current:        #5070 HOOK Sensor found to be 6.5% high
                              during Spring Pass 2000 comparison
                        #5072 KETC Monthly QA indicates 5-10%
                              high bias
                        #5079 WASH Sensor found to be 23% high
                              during Spring Pass 2000 comparison
                        #5091 WIST Sensor found to be 5.5% low
                              during Spring Pass 2000 comparison
                        #5097 BESS Sensor found to be 10% high 
                              during Spring Pass 2000 comparison
                        #5099 MEDF Sensor found to be 8% low    
                              during Spring Pass 2000 comparison
                        #5101 WALT Sensor found to be 10% low
                              during Spring Pass 2000 comparison
        Added:          None
        Resolved:       #5009 SLAP Corrected SRAD problems by
                              replacing bad RH switch

RAIN    Current:        #5078 BURN Gauge recorded no rain during
                              radar-indicated rain event
                        #5098 BESS Gauge found to be double-tipping
                              on one side of bucket during Spring
                              Pass 2000 test
        Added:          None
        Resolved:       #5075 PUTN Replaced bad switch                

TA9M    Current:        None
        Added:          None
        Resolved:       #5008 SLAP Corrected TA9M problems by
                              cleaning corroded negative ground

WS2M    Current:        None
        Added:          None 
        Resolved:       None

TS10    Current:        None
        Added:          None
        Resolved:       #5007 SLAP Corrected TS10 problems by
                              cleaning corroded negative ground
                        #5056 SKIA Tightened down power ground port

TB10    Current:        #5096 BOWL Sensor reports 10 C warm bias
                              during and after rain events
        Added:          None
        Resolved:       #5057 SKIA Tightened down power ground port

TS05    Current:        None
        Added:          None
        Resolved:       #5058 SKIA Tightened down power ground port

TB05    Current:        None
        Added:          None
        Resolved:       #5059 SKIA Tightened down power ground port

TS30    Current:        #5005 CHIC Sensor stuck at -273.1
        Added:          None
        Resolved:       #5012 SALL Replaced sensor reporting
                              unreasonable values
                        #5060 SKIA Tightened down power ground port

----------------------------------------------------------------
                                ARS QA REPORT
----------------------------------------------------------------

TAIR    Current:        None
        Added:          None
        Resolved:       None

RELH    Current:        None 
        Added:          None
        Resolved:       None

SRAD    Current:        None
        Added:          None
        Resolved:       None

RAIN    Current:        #5092 A181 Gauge recorded no rain during
                              heavy rain event
        Added:          None
        Resolved:       #5055 A133 Repaired vandalized gauge
                        
TS05    Current:        None
        Added:          None
        Resolved:       None

TS10    Current:        None
        Added:          None
        Resolved:       None

TS15    Current:        #5071 A136 Monthly QA indicates 3-4 C 
                              warm bias
        Added:          None
        Resolved:       None

TS30    Current:        None  
        Added:          None
        Resolved:       None

========================================================================

LEGEND
TAIR    Air Temperature measured at 1.5 meters
RELH    Relative Humidity measured at 1.5 meters
WDIR    Wind Direction measured at 10 meters
WSPD    Wind Speed measured at 10 meters
PRES    Pressure
SRAD    Incident Solar Radiation
RAIN    Rainfall
TA9M    Air Temperature measured at 9 meters
WS2M    Wind Speed measured at 2 meters
TS10    Soil Temperature measured at 10 cm under native sod
TB10    Soil Temperature measured at 10 cm under bare soil
TS05    Soil Temperature measured at 5 cm under native sod
TB05    Soil Temperature measured at 5 cm under bare soil
TS15    Soil Temperature measured at 15 cm under native sod
TS30    Soil Temperature measured at 30 cm under native sod

=======================================================================
Suggestions: 
Measurements:sgp05okmX1.b1:
  • solar radiation(srad)
  • average wind speed at 2m(wspd_2m)
  • standard deviation of wind speed(wspd_sigma)
  • Relative Humidity (hybrid-b grid)(rh)
  • vector average wind magnitude(wvec_10m)
  • air temperature at 1.5m(tdry_1_5m)
  • accumulated rainfall since 00GMT except at 00 GMT, the number given is the total
    accumulation for the past 24 hours(prec_amt)
  • standard deviation of wind direction(wdir_sigma)
  • vector average of wind direction measured at 10m(wdir_10m)
  • average wind run (arithmetic average speed) at 10m(wspd_10m)
  • air temperature at 9m(tdry_9m)
  • maximum 3-second wind speed within the 5-minute averaging period(wspd_max)
  • Retrieved pressure profile(pres)
more
sgp05okmX1.a1:
  • accumulated rainfall since 00GMT except at 00 GMT, the number given is the total
    accumulation for the past 24 hours(prec_amt)
  • vector average wind magnitude(wvec_10m)
  • Retrieved pressure profile(pres)
  • standard deviation of wind speed(wspd_sigma)
  • vector average of wind direction measured at 10m(wdir_10m)
  • air temperature at 1.5m(tdry_1_5m)
  • average wind run (arithmetic average speed) at 10m(wspd_10m)
  • maximum 3-second wind speed within the 5-minute averaging period(wspd_max)
  • average wind speed at 2m(wspd_2m)
  • Relative Humidity (hybrid-b grid)(rh)
  • air temperature at 9m(tdry_9m)
  • solar radiation(srad)
  • standard deviation of wind direction(wdir_sigma)
more
sgp15okmX1.b1:
  • soil temperature at 10cm beneath bare soil(tbare10)
  • soil temperature at 30 cm beneath natural sod cover(tsoil30)
  • 10 cm soil temp(tsoil10)
  • soil temperature at 5 cm beneath bare soil(tbare5)
  • soil temperature at 5 cm beneath natural sod cover(tsoil5)
more
sgp15okmX1.a1:
  • soil temperature at 5 cm beneath natural sod cover(tsoil5)
  • 10 cm soil temp(tsoil10)
  • soil temperature at 5 cm beneath bare soil(tbare5)
  • soil temperature at 10cm beneath bare soil(tbare10)
  • soil temperature at 30 cm beneath bare soil(tbare30)
more

Close this window