DQRID : D010307.17
Start DateStart TimeEnd DateEnd Time
05/14/2000120006/06/20001805
more
Subject:
SGP/EBBR/E8 - E8 EBBR AEM Stuck In One Position
DataStreams:sgp30ebbrE8.b1, sgp15ebbrE8.b1, sgp5ebbrE8.b1
Description:
The raw temperature and humidity data is incorrect and thus Bowen ratio, 
and half hour sensible and latent heat flux are incorrect for much of this period.  Please 
look at the home signal qc to determine whether the data is indeed incorrect.

Normally I do not submit DQRs for this condition, but the frequency of
the problem was high for this site.
Suggestions: 
Measurements:sgp5ebbrE8.b1:
  • Top T/RH sensor temperature(temp_trh_top)
  • Bottom air temperature(temp_air_bottom)
  • Bottom relative humidity (fractional)(rh_bottom_fraction)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
  • Bottom vapor pressure(vapor_pressure_bottom)
  • Top relative humidity (fractional)(rh_top_fraction)
  • Top vapor pressure(vapor_pressure_top)
  • Top air temperature(temp_air_top)
more
sgp15ebbrE8.b1:
  • Right air temperature(temp_air_right)
  • Left air temperature(temp_air_left)
  • Left T/RH sensor temperature (resistance ratio)(temp_trh_left_rr)
  • Right relative humidity (mV)(rh_right_mv)
  • Left relative humidity (mV)(rh_left_mv)
  • Right T/RH sensor temperature (resistance ratio)(temp_trh_right_rr)
more
sgp30ebbrE8.b1:
  • Bottom vapor pressure(vapor_pressure_bottom)
  • Surface latent heat flux(latent_heat_flux)
  • Bottom air temperature(temp_air_bottom)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
  • Bottom relative humidity (fractional)(rh_bottom_fraction)
  • Surface sensible heat flux(sensible_heat_flux)
  • Top relative humidity (fractional)(rh_top_fraction)
  • Top vapor pressure(vapor_pressure_top)
  • Bowen ratio(bowen_ratio)
  • Top T/RH sensor temperature(temp_trh_top)
  • Top air temperature(temp_air_top)
more

Close this window