Subject: | SGP EBBR E25 - E25 EBBR Soil Heat Flow #1 Incorrect |
DataStreams: | sgp30ebbrE25.b1, sgp15ebbrE25.b1
|
Description: | The #1 soil heat flow sensor developed a +60 W m-2 bias
and thus indicated higher soil heat flows than the other
sensors. This results in slightly higher sensible and latent heat
fluxes than is correct. The sensor was replaced on 2/21/01. |
Suggestions: | |
Measurements: | sgp15ebbrE25.b1: - Soil heat flow 1 (mV)(soil_heat_flow_1_mv)
more
sgp30ebbrE25.b1: - Surface latent heat flux(latent_heat_flux)
- Surface soil heat flux, average of fluxes 1-5(surface_soil_heat_flux_avg)
- Soil heat flow 1(soil_heat_flow_1)
- Surface soil heat flux 1(surface_soil_heat_flux_1)
- Surface sensible heat flux(sensible_heat_flux)
- Soil heat flow 1, corrected for soil moisture(corr_soil_heat_flow_1)
more
|