SGP EBBR E8 - E8 EBBR Soil Heat Flow #1 Incorrect
DataStreams:sgp30ebbrE8.b1, sgp15ebbrE8.b1
Description:
Soil Heat Flow #1 was frequently large negative or large positive and
was incorrect.  The indicated measurements were also incorrect as a result.
Correct sensible and latent heat fluxes can be determined by using the
other four sets of soil measurements to determine the energy balance.
Suggestions: 
Measurements:sgp15ebbrE8.b1:
  • Soil heat flow 1 (mV)(soil_heat_flow_1_mv)
more
sgp30ebbrE8.b1:
  • Soil heat flow 1(soil_heat_flow_1)
  • Surface latent heat flux(latent_heat_flux)
  • Surface soil heat flux 1(surface_soil_heat_flux_1)
  • Surface sensible heat flux(sensible_heat_flux)
  • Soil heat flow 1, corrected for soil moisture(corr_soil_heat_flow_1)
  • Surface soil heat flux, average of fluxes 1-5(surface_soil_heat_flux_avg)