DQRID : D020115.2
Start DateStart TimeEnd DateEnd Time
04/26/2001150506/07/20011501
07/05/2001180007/30/20010201
07/30/2001034509/08/20011701
10/02/2001094501/12/20020001
09/13/2001053009/13/20011531
06/20/2001164607/04/20011101
09/13/2001190009/27/20011416
more
Subject:
SGP/EEBR/E2 - AEM Stopped In One Position
DataStreams:sgp15ebbrE2.b1, sgp5ebbrE2.b1, sgp30ebbrE2.b1
Description:
The AEM kept stopping in one of three positions, none of which allow
sensible heat flux, latent heat flux, or Bown ratio to be calculated
correctly.  These and the gradient measurements are incorrect for the
period indicated.

The AEM stopped in either the home15 position (home signal about 53),
the home 30 position (home signal about 23), or inbetween these two
(home signal 1 to 2).
Suggestions: 
Measurements:sgp30ebbrE2.b1:
  • Top relative humidity (fractional)(rh_top_fraction)
  • Bottom relative humidity (fractional)(rh_bottom_fraction)
  • Bottom air temperature(temp_air_bottom)
  • Top vapor pressure(vapor_pressure_top)
  • Surface sensible heat flux(sensible_heat_flux)
  • Bowen ratio(bowen_ratio)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
  • Bottom vapor pressure(vapor_pressure_bottom)
  • Surface latent heat flux(latent_heat_flux)
  • Top air temperature(temp_air_top)
  • Top T/RH sensor temperature(temp_trh_top)
more
sgp5ebbrE2.b1:
  • Top T/RH sensor temperature(temp_trh_top)
  • Bottom vapor pressure(vapor_pressure_bottom)
  • Top relative humidity (fractional)(rh_top_fraction)
  • Top air temperature(temp_air_top)
  • Bottom air temperature(temp_air_bottom)
  • Bottom relative humidity (fractional)(rh_bottom_fraction)
  • Top vapor pressure(vapor_pressure_top)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
more
sgp15ebbrE2.b1:
  • Right relative humidity (mV)(rh_right_mv)
  • Right air temperature(temp_air_right)
  • Right T/RH sensor temperature (resistance ratio)(temp_trh_right_rr)
  • Left relative humidity (mV)(rh_left_mv)
  • Left T/RH sensor temperature (resistance ratio)(temp_trh_left_rr)
  • Left air temperature(temp_air_left)
more