Subject: | SGP/SMOS/E20 - Tower lowered for work on instrumentation |
DataStreams: | sgp30smosE20.a1, sgp1smosE20.a0
|
Description: | Due to tower being lowered to work on instrumentation between
1700 and 1830 GMT on 03 NOV 94, all wind data are incorrect. |
Suggestions: | All wind data taken during this period should be
flagged as incorrect. |
Measurements: | sgp1smosE20.a0: - Standard Deviation of wind direction(sd_deg)
- Wind Speed(wspd)
- Wind Direction(wdir)
- Wind Speed (vector averaged)(wspd_va)
more
sgp30smosE20.a1: - Standard Deviation of Wind Speed(sd_wspd)
- Standard Deviation of wind direction(sd_deg)
- Wind Speed(wspd)
- Wind Direction(wdir)
- Wind Speed (vector averaged)(wspd_va)
more
|