Subject: | SGP/EBBR/E18 - Reference Temperature Incorrect |
DataStreams: | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1
|
Description: | The reference temperature was incorrect during the checks of the left air temperature
sensor, leading to all gradient measurements, Bowen ratio, sensible heat flux, latent heat
flux, soil temperature, and soil moisture measurements being incorrect. |
Suggestions: | |
Measurements: | sgp30ebbrE18.b1: - Bowen ratio(bowen_ratio)
- Soil moisture 5, gravimetric(soil_moisture_5)
- Soil moisture 4, gravimetric(soil_moisture_4)
- Change in energy storage 5, 0-5 cm soil layer(energy_storage_change_5)
- Change in energy storage 1, 0-5 cm soil layer(energy_storage_change_1)
- Change in energy storage 2, 0-5 cm soil layer(energy_storage_change_2)
- Change in energy storage 3, 0-5 cm soil layer(energy_storage_change_3)
- Bottom air temperature(temp_air_bottom)
- Change in energy storage 4, 0-5 cm soil layer(energy_storage_change_4)
- Soil moisture 1, gravimetric(soil_moisture_1)
- Soil moisture 3, gravimetric(soil_moisture_3)
- Soil moisture 2, gravimetric(soil_moisture_2)
- Reference temperature in enclosure(temp_reference)
- Surface latent heat flux(latent_heat_flux)
- Soil heat capacity 1(soil_heat_capacity_1)
- Soil temperature 1(soil_temp_1)
- Soil heat capacity 2(soil_heat_capacity_2)
- Surface sensible heat flux(sensible_heat_flux)
- Top air temperature(temp_air_top)
- Soil temperature mean 3(soil_temp_3)
- Soil heat capacity 3(soil_heat_capacity_3)
- Soil temperature 2(soil_temp_2)
- Soil heat capacity 4(soil_heat_capacity_4)
- Soil heat capacity 5(soil_heat_capacity_5)
- Half hour averaged soil temperature 5(soil_temp_5)
- Half hour averaged soil temperature 4(soil_temp_4)
more
sgp15ebbrE18.b1: - Left air temperature(temp_air_left)
- Right air temperature(temp_air_right)
more
sgp5ebbrE18.b1: - Top T/RH sensor temperature(temp_trh_top)
- Bottom air temperature(temp_air_bottom)
- Top air temperature(temp_air_top)
- Bottom T/RH sensor temperature(temp_trh_bottom)
more
|