DQRID : D020717.27
Start DateStart TimeEnd DateEnd Time
11/01/2001000006/30/20022356
more
Subject:
SGP/EBBR/E19 - Reprocess: Soil Temperature #3 Incorrect
DataStreams:sgp30ebbrE19.b1
Description:
Soil Temperature 3 was incorrect for the period indicated, causing average soil flow, 
latent heat flux, and sensible heat flux to be incorrect also.

Average soil heat flow, sensible heat flux, and latent heat flux can be recalculated using 
the remaining good sets of soil sensors as follows:

ave_shf = (g1 + g2 + g4 + g5)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(q + e + ave_shf)
Suggestions: 
Measurements:sgp30ebbrE19.b1:
  • Surface soil heat flux, average of fluxes 1-5(surface_soil_heat_flux_avg)
  • Change in energy storage 3, 0-5 cm soil layer(energy_storage_change_3)
  • Soil temperature mean 3(soil_temp_3)
  • Surface sensible heat flux(sensible_heat_flux)
  • Surface latent heat flux(latent_heat_flux)
  • Surface soil heat flux 3(surface_soil_heat_flux_3)
more