DQRID : D020717.49
Start DateStart TimeEnd DateEnd Time
02/23/2002174502/23/20021801
03/06/2002191503/07/20021901
03/05/2002201503/06/20020201
02/24/2002004502/25/20020201
02/22/2002201502/22/20022101
more
Subject:
SGP/EBBR/E20 - Reprocess: Soil Temperature #3 Incorrect
DataStreams:sgp30ebbrE20.b1
Description:
Soil temperature 3 was incorrect during the indicated periods.

Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can 
be recalculated using the remaining good sets of soil sensors as follows:

ave_shf = (g1 + g2 + g4 + g5)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(q + e + ave_shf)
Suggestions: 
Measurements:sgp30ebbrE20.b1:
  • Change in energy storage 3, 0-5 cm soil layer(energy_storage_change_3)
  • Surface soil heat flux 3(surface_soil_heat_flux_3)
  • Surface latent heat flux(latent_heat_flux)
  • Soil temperature mean 3(soil_temp_3)
  • Surface soil heat flux, average of fluxes 1-5(surface_soil_heat_flux_avg)
  • Surface sensible heat flux(sensible_heat_flux)
more

Close this window