DQRID : D020717.8
Start DateStart TimeEnd DateEnd Time
01/30/2002120001/30/20021201
more
Subject:
SGP/EBBR/E12 - Reprocess: Soil Moisture 4 and 5 Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Soil moisture measurements from sets 4 and 5 were incorrect, leading to many other 
incorrect measurements calculated using them.

Average soil heat flow, sensible heat flux, and latent heat flux are affected; these can 
be recalculated using the remaining good sets of soil sensors as follows:
    ave_shf = (g1 + g2 + g3)/3
    e = -(q + ave_shf)/(1 + bowen)
    h = -(q + e + ave_shf)

Note:  D020717.6 reports Soil temperature sensor #3 was also bad during this
time, but for the very specific records affected by the soil moisture #4 and
#5 reporting incorrectly, soil temp #3 was okay.  Therefore the equations
given are correct.
Suggestions: 
Measurements:sgp30ebbrE12.b1:
  • Surface soil heat flux 4(surface_soil_heat_flux_4)
  • Surface soil heat flux 5(surface_soil_heat_flux_5)
  • Surface sensible heat flux(sensible_heat_flux)
  • Surface latent heat flux(latent_heat_flux)
  • Soil heat flow 5, corrected for soil moisture(corr_soil_heat_flow_5)
  • Soil heat capacity 5(soil_heat_capacity_5)
  • Soil heat flow 4, corrected for soil moisture(corr_soil_heat_flow_4)
  • Soil heat capacity 4(soil_heat_capacity_4)
  • Soil moisture 4, gravimetric(soil_moisture_4)
  • Soil moisture 5, gravimetric(soil_moisture_5)
  • Surface soil heat flux, average of fluxes 1-5(surface_soil_heat_flux_avg)
more