DQRID : D020726.2
Start DateStart TimeEnd DateEnd Time
01/18/2002001501/25/20022201
03/03/2002113003/07/20022031
more
Subject:
SGP/EBBR/E13 - Reprocess: Soil Heat Flow #1 and #2 Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Soil Heat Flow #1 and #2 were incorrect during the indicated period.

Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can 
be recalculated using the remaining good sets of soil sensors as follows:
   ave_shf = (g3 + g4 + g5)/3
   e = -(q + ave_shf)/(1 + bowen)
   h = -(q + e + ave_shf)
Suggestions: 
Measurements:sgp30ebbrE13.b1:
  • Surface soil heat flux 1(surface_soil_heat_flux_1)
  • Surface soil heat flux 2(surface_soil_heat_flux_2)
  • Soil heat flow 1(soil_heat_flow_1)
  • Surface sensible heat flux(sensible_heat_flux)
  • Surface soil heat flux, average of fluxes 1-5(surface_soil_heat_flux_avg)
  • Surface latent heat flux(latent_heat_flux)
  • Soil heat flow 1, corrected for soil moisture(corr_soil_heat_flow_1)
  • Soil heat flow 2, corrected for soil moisture(corr_soil_heat_flow_2)
  • Soil heat flow 2(soil_heat_flow_2)
more

Close this window