Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/30/2002 | 2030 | 01/08/2003 | 1730 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Temperature #3 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Temperature #3 was incorrect. The cause is apparently vandalism; the probe leads were cut. The indicated measurements that are calculated using soil temperature are also incorrect. DQR D030117.19 already provides the work-around for calculating correct sensible (h) and latent heat (e) fluxes, as soil heat flow #3 and soil heat flow #5 were also incorrect during this period. That work-around is repeated below. |
Suggestions: | Recalculate the average soil heat flow (ave_shf), latent heat flux (e), and sensible heat flux (h) using only soil sets 1, 2, and 4, as follows: ave_shf = (g1 + g2 + g4)/3 e = -(q + ave_shf)/(1 + Bowen) h = -(q + e + ave_shf) where q is net radiation and Bowen is the Bowen ratio. |
Measurements: | sgp30ebbrE20.b1: more
|