Subject: | SGP/EBBR/E20 - Reprocess: Net Rad Coefficients Incorrect |
DataStreams: | sgp5ebbrE20.b1, sgp30ebbrE20.b1
|
Description: | The Net Radiometer coefficients were incorrect in the CR10
program when the replacement EBBR unit was installed on
08/09/02.
The data can be easily corrected; see the Suggestion area below. |
Suggestions: | Positive net radiation measurements must be multiplied by 0.9989
Negative net radiaton measurements must be multiplied by 1.01283
Latent and Sensible Heat Fluxes can be recalculated from the following:
e = -(q + ave_shf)/(1 + Bowen)
h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE20.b1: - Surface latent heat flux(latent_heat_flux)
- Net radiation(net_radiation)
- Surface sensible heat flux(sensible_heat_flux)
more
sgp5ebbrE20.b1: - Net radiation(net_radiation)
more
|