DQRID : D030724.1
Start DateStart TimeEnd DateEnd Time
06/19/2003232407/21/20030824
more
Subject:
NSA/MWR/C2 - Thermally unstable
DataStreams:nsamwrlosC2.b1
Description:
The MWR became thermally unstable during periods when the ambient temperature exceeded 
about 28C. This situation was corrected when the mixer temperature was manually increased to 
about 35C.

Data are suspect when the blackbody temperature, tkbb, exceeds 296 K.
Suggestions: 
Measurements:nsamwrlosC2.b1:
  • Mean 31.4 GHz sky brightness temperature(tbsky31)
  • Total water vapor along LOS path(vap)
  • Averaged total liquid water along LOS path(liq)
  • Mean 23.8 GHz sky brightness temperature(tbsky23)
more