Subject:
SGP/IRT25m/C1 - Upwelling bias due to dirt on lens
DataStreams:sgpirt25mC1.00, sgpirt25mC1.a1
Description:
The upwelling IRT at 25m exhibited a positive bias compared to the PIR. The problem was 
corrected when the lens was cleaned.
Suggestions: 
Measurements:sgpirt25mC1.a1:
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)
  • Surface infra-red temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature, Maxima(sfc_ir_temp_max)
  • Instantaneous Surface Infra-red Temperature(inst_sfc_ir_temp)
  • Surface Infra-Red Temperature, Minima(sfc_ir_temp_min)