DQRID : D041011.3
Start DateStart TimeEnd DateEnd Time
10/08/2004113110/08/20041200
more
Subject:
TWP/SONDE/C1 - Bad RH at beginning of sounding
DataStreams:twpsondewnpnC1.b1
Description:
It appears that the RH sensor heating circuit failed during this portion of the sounding 
(approximately between 0km and 11km).  The RH oscillates rapidly between low (~1 %RH) and 
high (~80 %RH).  According to Vaisala these are symptoms of failure in the ASIC 
(application specific integrated circuit) that controls the heating.
Suggestions: 
null
Measurements:twpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Relative Humidity (hybrid-b grid)(rh)
more

Close this window