DQRID : D041216.4
Start DateStart TimeEnd DateEnd Time
12/13/2004200312/16/20041922
more
Subject:
NSA/METTWR/C1 - Reprocessed: Sonic wind speed units
DataStreams:nsamettwr4hC1.b1
Description:
Power fluctuations caused the Ultrasonic wind sensor to revert to default setting; wind 
speed was reported in mph rather than m/s for this time period.

Data were reprocessed to convert wind speeds from mph to m/s (0.44704 (m/s)/(mph))
Suggestions: 
Retrieve reprocessed data (nsasonicwind2dC1.b1)
Measurements:nsamettwr4hC1.b1:
  • Average X Component of Sonic Wind Speed(SonicX_AVG)
  • Average Y Component of Sonic Wind Speed(SonicY_AVG)
  • Average Sonic Static Speed of Sound(SonicS_AVG)
  • Sonic Arithmetic Mean Wind Speed(SonicWS_S_WVT)
  • Sonic Vector Averaged Wind Speed(SonicWS_U_WVT)