Subject: | NSA/METTWR/C1 - Ultrasonic Wind Sensor Values Incorrect |
DataStreams: | nsamettwr4hC1.b1
|
Description: | The values collected from the ultrasonic wind sensor were intermittently incorrect. Heavy
wet snow during blizzard condition was interfering with the ultrasonic readings. |
Suggestions: | None, as the cup anemometers were having problems also. |
Measurements: | nsamettwr4hC1.b1: - Average X Component of Sonic Wind Speed(SonicX_AVG)
- Average Y Component of Sonic Wind Speed(SonicY_AVG)
- Average Sonic Static Speed of Sound(SonicS_AVG)
- Wind direction vector mean standard deviation(SonicWD_SDU_WVT)
- Sonic Vector Averaged Wind Direction(SonicWD_DU_WVT)
- Sonic Arithmetic Mean Wind Speed(SonicWS_S_WVT)
- Sonic Vector Averaged Wind Speed(SonicWS_U_WVT)
more
|