DQRID : D061219.2
Start DateStart TimeEnd DateEnd Time
09/11/2003000001/31/20052359
more
Subject:
TWP/ARSCL/C2 - Reprocess: ARSCL CloudBasePrecipitation field incorrect
DataStreams:twpmmcrmode03v0091clothC2.c1, twpmmcrmode01v0101clothC2.c1, twpmmcrmode02v0071clothC2.c1,
twparsclcbh1clothC2.c1, twparscl1clothC2.c1
Description:
The CloudBasePrecipitation field is incorrect and has no physical meaning.  An ARSCL 
processing error occurred when the smet60s data stream format changed, causing the wrong data 
field to be used to supply precipitation measurements to the ARSCL VAP.	The error caused 
no significant degradation in other ARSCL fields, since manual quality control corrected 
any related errors.
Suggestions: 
Use twpsmet60sC2.b1 data stream field "precip_mean" for precipitation
measurements.
Measurements:twpmmcrmode01v0101clothC2.c1:
  • Microwave Radiometer Wet Window/Optical Rain Gauge Cloud Base Height(CloudBasePrecipitation)
more
twpmmcrmode03v0091clothC2.c1:
  • Microwave Radiometer Wet Window/Optical Rain Gauge Cloud Base Height(CloudBasePrecipitation)
more
twpmmcrmode02v0071clothC2.c1:
  • Microwave Radiometer Wet Window/Optical Rain Gauge Cloud Base Height(CloudBasePrecipitation)
more
twparscl1clothC2.c1:
  • Microwave Radiometer Wet Window/Optical Rain Gauge Cloud Base Height(CloudBasePrecipitation)
more
twparsclcbh1clothC2.c1:
  • Microwave Radiometer Wet Window/Optical Rain Gauge Cloud Base Height(CloudBasePrecipitation)
more

Close this window