Subject: | NSA/MET/C1 - 20m T/RH sensor failure |
DataStreams: | nsatwrC1.b1
|
Description: | The 20m temperature and RH were erratic and incorrect resulting in incorrect vapor
pressure calculations. The sensor was damaged by voltage spikes on the power lines. |
Suggestions: | Use 10m or 40m level data as proxy |