DQRID : D111101.1
Start DateStart TimeEnd DateEnd Time
09/25/2011000010/05/20110444
more
Subject:
GAN/GNDRAD/M1 - Incorrect up_long_hemisp
DataStreams:gangndrad60sM1.b1, gangndrad20sM1.a0
Description:
The up_long_hemisp values from the pyrgeometer were much too low, hovering near or just 
above 100 W/m^2.  This was particularly noticeable when comparing these values to those 
derived from the surface IRT.   

On 10/05/11, at 0348Z, tower was lowered for removal of PIR SN35836 and installation of 
PIR SN35839; tower raised at 0444Z. Following installation of PIR SN35839, data quality 
plots indicate proper up_long_hemisp values.
Suggestions: 
Measurements:gangndrad20sM1.a0:
  • Instantaneous Upwelling Pyrgeometer Dome Thermistor Resistance, Pyrgeometer(inst_up_long_hemisp_dome_resist)
  • Instantaneous Upwelling Pyrgeometer Thermopile Pyrgeometer(inst_up_long_hemisp_tp)
  • Instantaneous Upwelling Pyrgeometer Case Thermistor Resistance, Pyrgeometer(inst_up_long_hemisp_case_resist)
more
gangndrad60sM1.b1:
  • 10 meter Upwelling Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
  • Upwelling longwave hemispheric irradiance, pyrgeometer, maxima(up_long_hemisp_max)
  • Instantaneous Upwelling Pyrgeometer Case Thermistor Temperature(inst_up_long_hemisp_case_temp)
  • Instantaneous Upwelling Pyrgeometer Thermopile Pyrgeometer(inst_up_long_hemisp_tp)
  • Upwelling Longwave Hemispheric Irradiance, Pyrgeometer, Minima(up_long_hemisp_min)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer,
    Standard Deviation(up_long_hemisp_std)
  • Instantaneous Upwelling Pyrgeometer Dome Thermistor Temperature(inst_up_long_hemisp_dome_temp)
more