Description: | See below for details of reprocessing that was completed on 20150213. Original
DQR category: 4 (Red, Incorrect).
-----------------------------------------------------------
Applied calibration coefficient and serial number for down_short_diffuse was incorrect for
the specified period.
Perform the following calculation to correct the data,
DD= downwelling diffuse instrument:
Old Calibration coefficient = 114.74[W/m2\mV]
New Calibration Coefficient = 109.51[W/m2\mV]
DD(new)[W/m2]=( DD(old)[W/m2]/ 114.74 [W/m2\mV] )* 109.51 [W/m2/mV] |
Measurements: | sgpbrs20sC1.a0: - Instantaneous uncorrected downwelling shortwave diffuse, shaded pyranometer
thermopile voltage(inst_diffuse) more
sgpbrsC1.b1: - Downwelling Shortwave Diffuse Hemispheric Irradiance, Pyrgeometer, Minima(down_short_diffuse_hemisp_min)
- Downwelling Shortwave Diffuse Hemispheric Irradiance, Pyranometer, Standard
Deviation(down_short_diffuse_hemisp_std) - Downwelling shortwave diffuse hemispheric irradiance, pyranometer, maxima(down_short_diffuse_hemisp_max)
- Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer(down_short_diffuse_hemisp)
more
|