DQRID : D120301.2
Start DateStart TimeEnd DateEnd Time
06/12/2011050006/15/20110000
more
Subject:
SGP/RAIN/C1 - Lightning strike
DataStreams:sgprainC1.b1
Description:
A lightning strike took out the instrument on 6/12.  Error_latch and stat_latch flags were 
tripped and the instrument failed to record precip measured by co-located instruments 
(e.g. on 6/13).  Voltage and other data fields were also very erratic.

Instrument was replaced and normal operations resumed on 20110615.
Suggestions: 
Use precip data from MET, DISDROMETER or VDIS datasreams
Measurements:sgprainC1.b1:
  • Total precipitation over one minute sampling period(precip)
  • Voltage minimum(volt_min)
  • The latch counter counts number of measurement scans within one minute.(scans_per_min)
  • Precipitation intensity(precip_rate)
  • Temperature average, sensor 1(temp1)
  • Temperature average, sensor 2(temp2)
  • Millimeters of precipitation accumulated in the gauge since t he last tare.(total_mm)
  • Temperature 3 inside the instrument enclosure(temp3)
  • Panel temperature average(ptemp)
  • Sensor 3 maximum weight(weight3)
  • Sensor 2 maximum weight(weight2)
  • Sensor 1 maximum weight(weight1)
  • Total maintenance count(maintenance_cnt)
  • Sensor status(stat_latch)
  • Frequency average, sensor 1(frequency1)
  • Frequency average, sensor 2(frequency2)
  • Frequency average, sensor 3(frequency3)
  • Record with error(error_latch)
  • Weight of accumulated precipitation in the gauge since the la st tare(total_weight)