DQRID : D120509.5
Start DateStart TimeEnd DateEnd Time
06/29/2003150008/06/20030500
11/30/2001000011/08/20021900
more
Subject:
SGP/QCRAD/E10 - Noisy upwelling longwave
DataStreams:sgpqcrad1longE10.s1, sgpqcrad1longE10.c2, sgpqcrad1longE10.s2, sgpqcrad1longE10.c1
Description:
Upwelling Infrared irradiance signals noisy resulting from problems with pyrgeometer 
signal cable connections.

Documented in instrument DQRs D030110.37, D030110.36, D031027.1
Suggestions: 
Don't use upwelling LW fluxes during this time period.
Measurements:sgpqcrad1longE10.c1:
  • 10 meter Upwelling Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
more
sgpqcrad1longE10.s1:
  • 10 meter Upwelling Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
more
sgpqcrad1longE10.s2:
  • 10 meter Upwelling Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
more
sgpqcrad1longE10.c2:
  • 10 meter Upwelling Longwave Hemispheric Irradiance, Pyrgeometer(up_long_hemisp)
more

Close this window