Subject:
PVC/ECOR/M1 - Vapor Pressure High
DataStreams:pvc30ecorM1.b1
Description:
The vapor pressure data from the ECOR was somewhat high. This is obvious as the MET vapor 
pressure was determined to be too high and the ECOR vapor pressure was just slightly 
higher than the MET measurement. This probably resulted in slightly too large LE as measured 
by the ECOR, by about 10%.
Suggestions: 
Measurements:pvc30ecorM1.b1:
  • rotated covariance wq(cvar_rot_wq)
  • covariance wq(cvar_wq)
  • mean water vapor concentration (q)(mean_q)
  • covariance of tq(cvar_tq)
  • variance of q(var_q)
  • latent heat flux(lv_e)
  • covariance uq(cvar_uq)
  • Covariance vq(cvar_vq)
  • Covariance qc(cvar_qc)
  • rotated covariance vq(cvar_rot_vq)
  • Rotated covariance uq(cvar_rot_uq)
more