DQRID : D130815.1
Start DateStart TimeEnd DateEnd Time
06/25/2012000008/28/20122359
more
Subject:
PVC/QCRAD/M1 - PSP IR loss not corrected due to ventilation problems
DataStreams:pvcqcrad1longM1.c1
Description:
During this period the ventilator fan for the PSP is not working as described in DQR 
D120913.1. This changes the relationship between the PIR and PSP (because the PIR ventilation 
is correct during this time), making the IR loss correction incorrect. Thus the PSP 
measured shortwave irradiance is more uncertain and should be used with caution. This is not 
generally a problem when using the recommended variable for downward shortwave irradiance, 
BESW, which is usually the sum of the measured direct and diffuse irradiances during 
this period.
Suggestions: 
null
Measurements:pvcqcrad1longM1.c1:
  • Down-welling unshaded pyranometer voltage(down_short_hemisp)
more