Subject: | TWP/RL/C3 - Missing T1 and/or T2 (rotational Raman) channels |
DataStreams: | twprlC3.a0, twprlprofmerge1turnC3.c0, twp60rlproftemp1newsC3.c0, twp10rlproftemp1newsC3.c0
|
Description: | Data for the T1 and/or T2 (rotation Raman) channels are missing due to failures of
multiple high voltage power supplies for PMTs. As a result, it is not be possible to derive
temperature profiles from the Raman lidar during the effected period.
Temperature profile data from the Raman lidar are incorrect. Do not use for analysis. |
Suggestions: | Do not use temperature profiles during the period covered by this DQR. |
Measurements: | twprlprofmerge1turnC3.c0: - Glue coefficient (slope) for high temperature #2 channel(t2_counts_high_glue_coef_slope)
- Mean electronic background subtracted from the high channel temperature #2
analog signal(electronic_background_t2_analog_high) - Glue coefficient (offset) for high temperature #2 channel(t2_counts_high_glue_coef_offset)
- Mean electronic background subtracted from the high channel temperature #1
analog signal(electronic_background_t1_analog_high) - Glue coefficient (offset) for high temperature #1 channel(t1_counts_high_glue_coef_offset)
- Number of photons counted in the temperature 2 channel(t2_counts_high)
- Number of photons counted in the temperature 1 channel(t1_counts_high)
- Glue coefficient (slope) for high temperature #1 channel(t1_counts_high_glue_coef_slope)
more
twprlC3.a0: - Number of photons counted in the temperature 1 channel(t1_counts_high)
- Number of photons counted in the temperature 2 channel(t2_counts_high)
- Summed analog signal in the temperature 2 channel(t2_analog_high)
- Summed analog signal in the temperature 1 channel(t1_analog_high)
more
twp60rlproftemp1newsC3.c0: - Background of the rotational Raman signal at 354nm(tp2_bkg)
- Chi-square associated with the mean overlap correction(overlap_chisq)
- Error in the background subtracted rotational Raman signal at 354nm(tp2_error)
- Raw rotational ratio error(rot_raman_ratio_error)
- Background of the rotational Raman signal at 353nm(tp1_bkg)
- Correlation coefficient associated with the mean overlap correction(overlap_corr)
- Calibration coefficient a(a_coef)
- Error in the background subtracted rotational Raman signal at 353nm(tp1_error)
- Error in calibration coefficient b(b_coef_error)
- Calibrated rotational Raman temperature(rot_raman_temperature)
- Error in the background of the rotational Raman signal at 354nm(tp2_bkg_error)
- Solar background correction factor applied to the calibration coefficient b(b_coef_scale)
- Error in calibrated rotational Raman temperature(rot_raman_temperature_error)
- Calibration coefficient b(b_coef)
- Raw rotational Raman ratio(rot_raman_ratio)
- Solar background correction factor applied to the calibration coefficient a(a_coef_scale)
- Error in calibration coefficient a(a_coef_error)
- Overlap function(overlap_function)
- Error in the background of the rotational Raman signal at 353nm(tp1_bkg_error)
- Background subtracted rotational Raman signal at 354nm(tp2)
- Background subtracted rotational Raman signal at 353nm(tp1)
more
twp10rlproftemp1newsC3.c0: - Error in calibrated rotational Raman temperature(rot_raman_temperature_error)
- Background subtracted rotational Raman signal at 354nm(tp2)
- Background subtracted rotational Raman signal at 353nm(tp1)
- Calibrated rotational Raman temperature(rot_raman_temperature)
- Error in calibration coefficient a(a_coef_error)
- Solar background correction factor applied to the calibration coefficient a(a_coef_scale)
- Raw rotational ratio error(rot_raman_ratio_error)
- Calibration coefficient a(a_coef)
- Background of the rotational Raman signal at 353nm(tp1_bkg)
- Correlation coefficient associated with the mean overlap correction(overlap_corr)
- Overlap function(overlap_function)
- Error in calibration coefficient b(b_coef_error)
- Solar background correction factor applied to the calibration coefficient b(b_coef_scale)
- Raw rotational Raman ratio(rot_raman_ratio)
- Background of the rotational Raman signal at 354nm(tp2_bkg)
- Error in the background subtracted rotational Raman signal at 353nm(tp1_error)
- Error in the background of the rotational Raman signal at 353nm(tp1_bkg_error)
- Error in the background subtracted rotational Raman signal at 354nm(tp2_error)
- Error in the background of the rotational Raman signal at 354nm(tp2_bkg_error)
- Chi-square associated with the mean overlap correction(overlap_chisq)
- Calibration coefficient b(b_coef)
more
|