DQRID : D140326.5
Start DateStart TimeEnd DateEnd Time
01/23/2014000009/13/20142359
more
Subject:
TMP/MET/M1 - Wind sensor siting not ideal
DataStreams:tmpmetM1.b1, tmpmetM1.00
Description:
According to the manual, the wind sensor should ideally be mounted higher than any object 
within a 300 meter radius. This particular site is bordered by approximately 20 meter 
tall trees (the wind sensor is mounted at 10 meters) from about due west to south/southeast, 
at a distance approximately 60 meters or less. Please reference the instrument handbook 
or contact the mentor for more information.
Suggestions: 
Measurements:tmpmetM1.b1:
  • Wind speed arithmetic mean(wspd_arith_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • Wind direction vector mean standard deviation(wdir_vec_std)
  • Wind speed vector mean(wspd_vec_mean)
more
tmpmetM1.00:
  • (Raw data stream - documentation not supported)
more