Measurements: | maoaosnephdryM1.a1: - Pressure inside reference nephelometer(P_Neph_Dry)
- Nephelometer-specific flags(f2_flags)
- Temperature, inside nephelometer(T_Neph_Vol_Dry)
- Aerosol back-hemispheric light scattering coefficient, nominal blue wavelength
at dry or reference RH(Bbs_B_Dry_Neph3W) - Impactor setting in terms of aerodynamic diameter cut off(impactor_setting)
- Relative humidity at reference nephelometer inlet(RH_Neph_Inlet_Dry)
- Aerosol total light scattering coefficient, nominal red wavelength at dry or
reference RH(Bs_R_Dry_Neph3W) - Aerosol back-hemispheric light scattering coefficient, nominal red wavelength at
dry or reference RH(Bbs_R_Dry_Neph3W) - Temperature, reference nephelometer inlet(T_Neph_Inlet_Dry)
- Relative humidity, inside reference nephelometer(RH_Neph_Vol_Dry)
- Aerosol total light scattering coefficient, nominal green wavelength at dry or
reference RH(Bs_G_Dry_Neph3W) - Aerosol back-hemispheric light scattering coefficient, nominal green wavelength
at dry or reference RH(Bbs_G_Dry_Neph3W) - Aerosol total light scattering coefficient, nominal blue wavelength at dry or
reference RH(Bs_B_Dry_Neph3W) more
maoaosnephwetM1.b1: - Aerosol total light scattering coefficient, nominal blue wavelength at ramped RH(Bs_B_Wet_Neph3W_2)
- Aerosol back-emispheric light scattering coefficient, nominal green wavelength
at ramped RH(Bbs_G_Wet_Neph3W_2) - Temperature, inside nephelometer(T_Neph_Vol_Wet)
- Pressure inside humidified nephelometer(P_Neph_Wet)
- Aerosol back-hemispheric light scattering coefficient, nominal red wavelength at
ramped RH(Bbs_R_Wet_Neph3W_2) - Impactor setting in terms of aerodynamic diameter cut off(impactor_setting)
- Sample temperature inside humidified nephelometer(T_Neph_Wet)
- Aerosol total light scattering coefficient, nominal green wavelength at ramped
RH(Bs_G_Wet_Neph3W_2) - Aerosol back-hemispheric light scattering coefficient, nominal blue wavelength
at ramped RH(Bbs_B_Wet_Neph3W_2) - Relative humidity, inside reference nephelometer(RH_Neph_Vol_Wet)
- Relative humidity, Humidograph nephelometer(RH_Neph_Wet)
- Aerosol total light scattering coefficient, nominal red wavelength at ramped RH(Bs_R_Wet_Neph3W_2)
- Temperature, reference nephelometer inlet(T_Neph_Inlet_Wet)
- Relative humidity at humidified nephelometer inlet(RH_Neph_Inlet_Wet)
more
maoaoscpcM1.a1: - Nozzle pressure(nozzle_pressure)
- Orifice pressure(orifice_pressure)
- Aerosol concentration averaged over times to match N_CCN(concentration)
- OPC laser current(laser_current)
- Ambient Temperature(ambient_temp)
- Condensation temperature(condensation_temp)
- Cabinet temperature(cabinet_temp)
- Optics temperature(optics_temp)
- Saturation temperature(saturation_temp)
more
maoaospsap3wM1.b1: - Impactor setting in terms of aerodynamic diameter cut off(impactor_setting)
- AOS Ba_R_CLAP3W transmittance, red channel(transmittance_R)
- Flow setpoint(dilution_flow_setpoint)
- Aerosol light absorption coefficient, nominal blue wavelength at dry or
reference RH(Ba_B_PSAP3W) - Mass flow(mass_flow)
- Aerosol light absorption coefficient, nominal green wavelength at dry or
reference RH(Ba_G_PSAP3W) - Aerosol light absorption coefficient, nominal red wavelength at dry or reference
RH(Ba_R_PSAP3W) - AOS Ba_B_CLAP3W transmittance, blue channel(transmittance_B)
- Dilution flow rate(dilution_flow)
- AOS PSAP3W transmittance, green channel(transmittance_G)
- Diffusion flow valve position(dilution_flow_valve_position)
- AOS Ba_B_CLAP3W_1 (NOAA) sample length, needed to calculate Beers Law(sample_length)
more
maoaosnephdryM1.b1: - Pressure inside reference nephelometer(P_Neph_Dry)
- Aerosol total light scattering coefficient, nominal green wavelength at dry or
reference RH(Bs_G_Dry_Neph3W_1) - Aerosol back-hemispheric light scattering coefficient, nominal blue wavelength
at dry or reference RH(Bbs_B_Dry_Neph3W_1) - Aerosol back-hemispheric light scattering coefficient, nominal red wavelength at
dry or reference RH(Bbs_R_Dry_Neph3W_1) - Temperature, reference nephelometer inlet(T_Neph_Inlet_Dry)
- Aerosol back-hemispheric light scattering coefficient, nominal green wavelength
at dry or reference RH(Bbs_G_Dry_Neph3W_1) - Aerosol total light scattering coefficient, nominal red wavelength at dry or
reference RH(Bs_R_Dry_Neph3W_1) - Relative humidity, reference nephelometer(RH_Neph_Dry)
- Impactor setting in terms of aerodynamic diameter cut off(impactor_setting)
- Aerosol total light scattering coefficient, nominal blue wavelength at dry or
reference RH(Bs_B_Dry_Neph3W_1) - Sample temperature inside reference nephelometer(T_Neph_Dry)
more
maoaosccn100M1.a1: - Bin number of lowest channel of OPC include in summation of N_CCN(N_CCN_bin_number)
- AOS CCN OPC laser current(CCN_laser_current)
- AOS CCN temperature of the optical particle counter(CCN_T_OPC)
- Size of upper limit of each CCN bin(CCN_upper_size_limit)
- Temperature difference between CCN_t_set_TEC3 and CCN_t_set_TEC1(CCN_temperature_gradient)
- AOS CCN logical value, indicating whether the instrument has reached thermal
gradient stabilization and is within 0.4 degrees C of the set point(CCN_temp_unstable_flag) - AOS CCN set point temperature for the inlet manifold(CCN_inlet_set)
- CCN Proportional valve voltage(CCN_proportional_valve_voltage)
- Cloud condensation nuclei number density(N_CCN)
- AOS CCN temperature of sample air entering the column(CCN_T_sample)
- Number of particles that are larger than 10um(CCN_overflow)
- AOS CCN sample pressure(CCN_P_sample)
- AOS CCN volumetric flowrate of sample air(CCN_Q_sample)
- AOS CCN number concentration by bin(N_CCN_dN)
- AOS CCN temperature of sample air at entrance to instrument(CCN_T_inlet)
- AOS CCN observed temperature at top of column(CCN_t_read_TEC1)
- AOS CCN set point for temperature at top of column(CCN_t_set_TEC1)
- AOS CCN observed temperature at middle of column(CCN_t_read_TEC2)
- AOS CCN (read) temperature at bottom of column(CCN_t_read_TEC3)
- AOS CCN voltage used by DMT for OPC diagnostic purposes(CCN_baseline_monitor)
- AOS CCN temperature of the nafion humidifier(CCN_T_nafion)
- AOS CCN set point for temperature at middle of column(CCN_t_set_TEC2)
- AOS CCN set point for temperature at bottom of column(CCN_t_set_TEC3)
- AOS CCN set point temperature for the optical particle counter (OPC)(CCN_OPC_set)
- AOS CCN volumetric flowrate of sheath air(CCN_Q_sheath)
- First stage monitor voltage(CCN_first_stage_monitor_voltage)
- CCN alarm code expressed as a summation of powers of 2. 0 indicates no detected
problem(CCN_alarm_code) - AOS CCN set temperature for the Nafion humidifier(CCN_nafion_set)
- AOS CCN sample saturation setpoint value reported by instrument(CCN_ss_set)
more
|