DQRID : D160520.5
Start DateStart TimeEnd DateEnd Time
05/10/2016190505/16/20160925
more
Subject:
AWR/MET/M1 - Probable instrument icing
DataStreams:awrmetM1.b1, awrmetM1.00
Description:
The temperature and relative humidity sensor behaved suspiciously during this time. 
Temperature and relative humidity readings did not trend inversely, as expected. Ice buildup on 
the instrument is the probable cause.
Suggestions: 
Do not use data.
Measurements:awrmetM1.b1:
  • Temperature mean(temp_mean)
  • Vapor pressure mean, calculated(vapor_pressure_mean)
  • Relative humidity observed by the Raman lidar(rh_mean)
more
awrmetM1.00:
  • (Raw data stream - documentation not supported)