DQRID : D940106.1
Start DateStart TimeEnd DateEnd Time
12/17/1993110012/29/19931700
more
Subject:
SGP/EBBR/E8 - Invalid data due to AEM fuse blow out at E8
DataStreams:sgp30ebbrE8.b1, sgp15ebbrE8.b1, sgp5ebbrE8.b1
Description:
On December 17, 1993, before 1100 GMT, the fuse in the AEM (Automatic
Exchange Mechanism) of Coldwater, KS (E8) EBBR blew out.  The AEM remained
nonfunctional until the fuse was replaced just before 1700 GMT on
December 29, 1993.  During the 1000 GMT half hour on December 17 the AEM
was hung up; this is clear from the home signal.  These situations resulted in
the following invalid data:

5 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
          vp_top, vp_bot, home

15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, mv_home, tair_r,
           tair_l

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h, home_15, home_30

Bowen, h, and e can not be recalculated from the 15 minute and/or 5 minute data
since we cannot determine the position of the sensors on the AEM from the home
signal; home signal is near zero when there is no power to the AEM.
Suggestions: 
Measurements:sgp5ebbrE8.b1:
  • Top T/RH sensor temperature(temp_trh_top)
  • Bottom air temperature(temp_air_bottom)
  • Bottom relative humidity (fractional)(rh_bottom_fraction)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
  • Bottom vapor pressure(vapor_pressure_bottom)
  • AEM position indicator(home_signal)
  • Top relative humidity (fractional)(rh_top_fraction)
  • Top vapor pressure(vapor_pressure_top)
  • Top air temperature(temp_air_top)
more
sgp15ebbrE8.b1:
  • Right air temperature(temp_air_right)
  • Left air temperature(temp_air_left)
  • Left T/RH sensor temperature (resistance ratio)(temp_trh_left_rr)
  • Right relative humidity (mV)(rh_right_mv)
  • Left relative humidity (mV)(rh_left_mv)
  • AEM position indicator(home_signal)
  • Right T/RH sensor temperature (resistance ratio)(temp_trh_right_rr)
more
sgp30ebbrE8.b1:
  • AEM position indicator 15 to 30 mins(home_signal_30)
  • Bottom vapor pressure(vapor_pressure_bottom)
  • Surface latent heat flux(latent_heat_flux)
  • Bottom air temperature(temp_air_bottom)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
  • Bottom relative humidity (fractional)(rh_bottom_fraction)
  • AEM position indicator 0 to 15 mins(home_signal_15)
  • Surface sensible heat flux(sensible_heat_flux)
  • Top relative humidity (fractional)(rh_top_fraction)
  • Top vapor pressure(vapor_pressure_top)
  • Bowen ratio(bowen_ratio)
  • Top T/RH sensor temperature(temp_trh_top)
  • Top air temperature(temp_air_top)
more