DQRID : D950815.2
Start DateStart TimeEnd DateEnd Time
08/01/1995150008/02/19951615
more
Subject:
SGP/EBBR/E13 - Low Battery Voltage and AEM Left on Manual
DataStreams:sgp5ebbrE13.b1, sgp30ebbrE13.b1
Description:
Low battery voltage caused some data values to be incorrect beginning at
1500 GMT on August 1, 1995.  The data should be carefully inspected to
determine which values are incorrect.

During replacement of the battery at the Central Facility EBBR on August
1, 1995, the AEM exchange toggle switch was left in the manual position,
which caused the right aspirator to remain in the home position until the
switch was correctly placed in the exchange position at 1616 GMT on August
2, 1995.  All 5, 15, and 30 minute values of temperature, relative humidity
, vapor pressure, bowen, e, and h are incorrect during the period. 15 and
30 minute values are also incorrect at 1630 GMT.
Suggestions: 
Measurements:sgp5ebbrE13.b1:
  • Bottom air temperature(temp_air_bottom)
  • Top air temperature(temp_air_top)
  • Top relative humidity (fractional)(rh_top_fraction)
  • Top T/RH sensor temperature(temp_trh_top)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
  • Bottom relative humidity (fractional)(rh_bottom_fraction)
  • Top vapor pressure(vapor_pressure_top)
  • Bottom vapor pressure(vapor_pressure_bottom)
more
sgp30ebbrE13.b1:
  • Bowen ratio(bowen_ratio)
  • Top T/RH sensor temperature(temp_trh_top)
  • Surface sensible heat flux(sensible_heat_flux)
  • Top relative humidity (fractional)(rh_top_fraction)
  • Bottom air temperature(temp_air_bottom)
  • Surface latent heat flux(latent_heat_flux)
  • Top air temperature(temp_air_top)
  • Bottom vapor pressure(vapor_pressure_bottom)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
  • Top vapor pressure(vapor_pressure_top)
  • Bottom relative humidity (fractional)(rh_bottom_fraction)
more