DQRID : D960202.2
Start DateStart TimeEnd DateEnd Time
02/01/1996112902/01/19961245
more
Subject:
SGP/SONDE/C1  - Bad pressure sounding
DataStreams:sgpsondewrpnC1.a1, sgpsondewrpnC1.a0
Description:
The surface pressure for this sounding was entered by the operator as 962.6. The first 
pressure value reported by the sonde is 962.4 hPa. The surface pressure in the previous 
(0533) and subsequent (1429) soundings were 983.3 and 985.7 respectively.  SMOS13 pressures 
were in the 983+ range during this same period.  It appears that the sonde pressure sensor 
was bad and was used as the source of the surface pressure (this is CF standard 
procedure). Both the pressure and altitude values for this sounding are likely incorrect.
Suggestions: 
Use data with caution
Measurements:sgpsondewrpnC1.a0:
  • Retrieved pressure profile(pres)
more
sgpsondewrpnC1.a1:
  • Retrieved pressure profile(pres)
more

Close this window