DQRID : D960508.2
Start DateStart TimeEnd DateEnd Time
05/02/1996144105/02/19961512
more
Subject:
SGP/EBBR/E7 - 3-month check
DataStreams:sgp5ebbrE7.b1, sgp30ebbrE7.b1
Description:
During EBBR 3-month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.  The period of incorrect
data for the EBBR is listed above; data times affected do not include the
beginning time and do include the ending time (data files are denoted by
the end time).
Suggestions: 
Measurements:sgp5ebbrE7.b1:
  • Bottom vapor pressure(vapor_pressure_bottom)
  • Top vapor pressure(vapor_pressure_top)
  • Bottom relative humidity (fractional)(rh_bottom_fraction)
  • Bottom air temperature(temp_air_bottom)
  • Top relative humidity (fractional)(rh_top_fraction)
  • Top T/RH sensor temperature(temp_trh_top)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
  • Top air temperature(temp_air_top)
more
sgp30ebbrE7.b1:
  • Top vapor pressure(vapor_pressure_top)
  • Surface latent heat flux(latent_heat_flux)
  • Top T/RH sensor temperature(temp_trh_top)
  • Bottom air temperature(temp_air_bottom)
  • Bowen ratio(bowen_ratio)
  • Top air temperature(temp_air_top)
  • Bottom relative humidity (fractional)(rh_bottom_fraction)
  • Bottom vapor pressure(vapor_pressure_bottom)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
  • Top relative humidity (fractional)(rh_top_fraction)
  • Surface sensible heat flux(sensible_heat_flux)
more