DQRID : D980513.6
Start DateStart TimeEnd DateEnd Time
02/12/1998093005/01/19981530
more
Subject:
SGP/EBBR/E15 - Left T/RH Probe Temperature Too Large
DataStreams:sgp5ebbrE15.b1, sgp30ebbrE15.b1, sgp15ebbrE15.b1
Description:
Beginning in February, the temperature of the left T/RH probe reported too
high a value at some times.  The frequency of the problem increased with
time until 28 April at 1520 GMT, when a defective probe was installed; the
latter probe temperature indicated very high values.  This continued until
1 May at 1530 GMT when a working probe was installed. Times of incorrect 
humidity probe temperatures can be determined by comparing 5 or 30 minute 
values of air temperature and humidity probe temperature; at these times the 
calculated bowen ratio, and the fluxes of latent and sensible heat are 
incorrect.

The incorrect variables were:

5  minute:  thum_top, thum_bot, vp_top, vp_bot
15 minute:  rr_thum_l
30 minute:  thum_top, thum_bot, vp_top, vp_bot, bowen, e, h
Suggestions: 
Measurements:sgp5ebbrE15.b1:
  • Top T/RH sensor temperature(temp_trh_top)
  • Bottom vapor pressure(vapor_pressure_bottom)
  • Top vapor pressure(vapor_pressure_top)
  • Bottom T/RH sensor temperature(temp_trh_bottom)
more
sgp15ebbrE15.b1:
  • Left T/RH sensor temperature (resistance ratio)(temp_trh_left_rr)
more
sgp30ebbrE15.b1:
  • Bottom T/RH sensor temperature(temp_trh_bottom)
  • Bottom vapor pressure(vapor_pressure_bottom)
  • Top vapor pressure(vapor_pressure_top)
  • Surface latent heat flux(latent_heat_flux)
  • Surface sensible heat flux(sensible_heat_flux)
  • Top T/RH sensor temperature(temp_trh_top)
  • Bowen ratio(bowen_ratio)
more