Data Quality Reports for Session: 100406 User: eluke Completed: 07/10/2006


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D050603.4SGP/SONDE/C1 - Surface pressure incorrectsgpsondewnpnC1.b1
D050725.1SGP/SONDE/C1 - Bad RH DatasgpsondewnpnC1.b1
D050811.5SGP/SONDE/C1 - Bad T/RH and surface P.sgpsondewnpnC1.b1
D050912.2SGP/SONDE/C1 - Temperature/RH incorrectsgplssondeC1.c1, sgpsondewnpnC1.b1
D051027.1SGP/SONDE/C1 - Bad RH DatasgpsondewnpnC1.b1
D060208.2SGP/SONDE/C1 - Mixed use of RS92-SGP and RS92-KL radiosondessgpsondewnpnC1.b1
D060227.2SGP/SONDE/C1 - Soundings done as part of dual-sonde flightssgpsondewnpnC1.b1


DQRID : D050603.4
Start DateStart TimeEnd DateEnd Time
05/11/2005053005/11/20050750
Subject:
SGP/SONDE/C1 - Surface pressure incorrect
DataStreams:sgpsondewnpnC1.b1
Description:
I think the operator inadvdertently mistyped a digit when entering the surface pressure 
value.  The value entered is 975.6 hPa but the value shown in the raw data file at launch 
is 972.6.  As a result, the absolute altitudes in this sounding will be slightly incorrect 
as will be the ascent rate during the first 30 seconds of flight.
Measurements:sgpsondewnpnC1.b1:
  • Ascent Rate(asc)
  • altitude above sea levelaltunits(alt)


Back To Table of Contents

DQRID : D050725.1
Start DateStart TimeEnd DateEnd Time
07/17/2005234707/18/20050141
Subject:
SGP/SONDE/C1 - Bad RH Data
DataStreams:sgpsondewnpnC1.b1
Description:
The RH values below 6 km are incorrect.  The problem relates to a failure of the GC25 
ground check set used before this particular sounding.  The failure seems to have affected 
the sensor calibration with the effect that one of the two sensors was reading artificially 
high.  Because the internal processing software uses the highest of the two sensor 
readings, the bad sensor value is chosen whenever it is not heated.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D050811.5
Start DateStart TimeEnd DateEnd Time
08/01/2005113208/01/20050116
Subject:
SGP/SONDE/C1 - Bad T/RH and surface P.
DataStreams:sgpsondewnpnC1.b1
Description:
Apparently multiple failures.  The radiosonde temperature sensor broke on launch causing 
an approximate 35 degC negative offset and as a result, the RH is incorrect.  Furthermore, 
it appears that the pressure sensor was off by approximately 4 hPa, though this would 
not affect the altitude calculation, the absolute pressure is wrong.
Measurements:sgpsondewnpnC1.b1:
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • pressure at constant pressure surface(pres)


Back To Table of Contents

DQRID : D050912.2
Start DateStart TimeEnd DateEnd Time
09/09/2005113209/09/20051332
Subject:
SGP/SONDE/C1 - Temperature/RH incorrect
DataStreams:sgplssondeC1.c1, sgpsondewnpnC1.b1
Description:
The temperature throughout this sounding is too high and as a result the RH values will be 
incorrect as well.  I'm not sure what is wrong here but the operators noted reasonable 
values (18.1 degC, 87%) in the log before launch.  Review of the raw data, however, shows 
the sonde reporting temperatures nearly 20 degC higher.  I suppose it is possible that 
the operator entered into the log the reference temperature from the GC25 ground check set 
rather than the temperature reported by the sonde - I can't think of any other 
explanation - there is no doubt that the temperature sensor on this sonde was bad.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)

sgplssondeC1.c1:
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Dry-Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D051027.1
Start DateStart TimeEnd DateEnd Time
10/24/2005114010/24/20051204
Subject:
SGP/SONDE/C1 - Bad RH Data
DataStreams:sgpsondewnpnC1.b1
Description:
The RH values during this sounding oscillate between reasonable values and near-zero 
values.  The oscillation is due to failure of the RH sensor heating process.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D060208.2
Start DateStart TimeEnd DateEnd Time
02/10/2006000012/31/20062359
Subject:
SGP/SONDE/C1 - Mixed use of RS92-SGP and RS92-KL radiosondes
DataStreams:sgpsondewnpnC1.b1
Description:
Because of a manufacturer's production problem, we will be using both RS92-SGP (GPS 
windfinding and RS92-KL (Loran windfinding) radiosondes at the SGP/CF starting February 10, 
2006.  The radiosonde type used for the each sounding may be determined by looking the 
metadata variable "launch_status" in the netCDF data files.
Measurements:sgpsondewnpnC1.b1:
  • east longitude for all the input platforms.(lon)
  • model zonal wind velocity(u_wind)
  • surface wind speed(wspd)
  • model meridional wind velocity(v_wind)
  • north latitude for all the input platforms.(lat)
  • Wind Direction(deg)
  • Wind Status(wstat)


Back To Table of Contents

DQRID : D060227.2
Start DateStart TimeEnd DateEnd Time
02/22/2006000002/27/20060000
Subject:
SGP/SONDE/C1 - Soundings done as part of dual-sonde flights
DataStreams:sgpsondewnpnC1.b1
Description:
The following soundings done during the subject time period were flown in dual-sonde mode 
in which the standard ARM RS92 radiosonde was attached to the same balloon with a NASA 
ATR (atmospheric temperature reference) radiosonde.  The radiosondes were separated by a 6' 
styrofoam bar.  To accommodate the additional weight, we used 1200g balloons rather than 
350g balloons.  Accordingly, we want to alert users that these soundings may reach 
higher altitudes than normal for ARM soundings and that the ascent rate may be somewhat 
higher.  The following soundings are affected:

Sequence  Date    UTC launch time
    1     2/22        0530
    2     2/22        1730
    3     2/22        2330 <---- No data: launch failure    
    4     2/23        0230
    5     2/23        0530
    6     2/23        1730    
    7     2/23        2030
    8     2/23        2330
    9     2/24        2330
   10     2/25        0215
   11     2/25        0509    
   12     2/25        1730
   13     2/25        1930
   14     2/25        2300
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Time offset from base_time(base_time)
  • surface wind speed(wspd)
  • model zonal wind velocity(u_wind)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • north latitude for all the input platforms.(lat)
  • Ascent Rate(asc)
  • pressure at constant pressure surface(pres)
  • Wind Direction(deg)
  • Wind Status(wstat)
  • east longitude for all the input platforms.(lon)
  • Dry-Bulb Temperature(tdry)
  • Time offset of tweaks from base_time(time_offset)
  • model meridional wind velocity(v_wind)
  • altitude above sea levelaltunits(alt)


Back To Table of Contents



END OF DATA